Examine Error Codes If you find that your power heater turns on but then keeps shutting off, this could indicate that you are having water pressure issues.
Get PriceSystems is few months old and goes into high pressure lockout (code L2) on the heat pump. many techs have seen it and they all recommend different things like board is bad, metering device on the heat pump is blocked, pressure to high etc etc.. Pressure too high has been mentioned by one tech and refuted to be fine by another.
Get PriceStart the water pump before turning on the Machine to avoid any damage. - Press power on/off on LED controller to turn on/off machine. - During the first start of machine, please check if there is any water leakage in the piping connection system. Then set suitable temperature.
Get Price28/03/ · 3 year old electric heat pump for my pool. Kept it Covered for the winter. Weather just got right to fire it up yesterday. Fan runs but does not seem to be heating water. I am not a good technician. A
Get PriceMikey Pipes - Pipe Doctor Plum Heating & Air
Get Price1 Hi guys, My heat pump decided to not run this morning. Got an E1 fault on the screen, which my manual says is High Gas Pressure Protection in the fault list. Anybody know what this means or what could be causing it? Heat pump is a Hayward HP65B (65,000 BTU) with vertical fan. Thanks Jeff Report ajw22 Gold Supporter TFP Guide Jul 21, 37,087
Get PriceReplace display board and wire harness Replace pressure switch. YES NO, Unit operates. Figure A dEFRefer To Page 10, Rotate dial counter clockwise to check for mis-adjustment. Switch will ‘close’ and reading will be zero Ohms. cSHRefer To Page 10, cOPRefer To Page 10, 2, What’s On The Display? On R-22 units abandon existing switch.
Get PriceThe most common cause of HP or HI error code is restricted water flow. An open bypass valve that allows the heat exchanger to be pressurized, but does not allow flow through it is a likely culprit. When heating a spa, there may not be sufficient flow through the system for proper operation at higher water temperatures.
Get Price02/12/ · How to fix it: Check that pool pump is receiving enough water. Ensure that your pool pump is sending water to the heat pump. For variable speed pool pumps, try putting
Get PriceHigh Freon pressure. This error code happens more often than not when there is low water flow and there is not enough water flowing through the heater to remove
Get PriceCheck that pool pump is sending water to the heat pump If possible, put the pump speed up a notch Check for any clogs or backups causing poor water circulation For refrigerant leaks and continuous sensor or fan issues, seek professional pool heat pump repair service Heat Siphon heat pump error code Hi P Hi P
Get PriceIf not, it could cause an injury due to the high speed running fan or an electrical shock. Do not continue to run the unit when there is something wrong or
Get PriceHP & HP6 - Low water flow in the unit or faulty high pressure control. Check water flow/backwash. The unit will show (HP6) after 6 HP faults. This will stop the unit for protection. FLo & FL3 - Possible causes: • The filter is in backwash position. • The filter pump is stopped. • The filter is dirty. • Shortage of water to pool pump.
Get PriceThe heat pump high pressure switch has cut off three (3) times in the same hour for one of the reasons above. What to do: The heat pump will not re-start after one of the protective devices
Get PriceBroken, split, pinched or disconnected air pressure switch tubing. Check tu and replace if necessary. Fan not operating. Correct fault or replace fan. Fan
Get PriceThe HP5 troubleshooting code tells you that there has been 5 high pressure faults within one call for heating or cooling. In other words, the heat pump tries
Get PriceWhen talking about gas heaters, are commonly known as a popular choice for pool and or spa owners because of how quickly they can heat the water. The waiting time to enjoy the warmer water is virtually nonexistent because of the high output they can provide (when referring to the spa as a pool will require a little bit of wait time).
Get PriceHP and HP 6 – Low water flow or faulty high pressure control in the unit. Check water flow / backwash. Unit 6 HP will show after the defect (HP 6). This will
Get PriceInternal safety devices may deactivate the heat pump with the following errors: ○. HIGH PRESSURE FAULT. ○. HP5 SYSTEM LOCKOUT. ○. LOW PRESSURE FAULT.
Get Price17/07/ · In ground pool Aqua Comfort Heat Pump throwing an HP code (high pressure switch open). I have cleaned the cell with mixture of acid and water and the flow of water to the heater is fine. Says the other possibility is a defective high-pressure switch. Is it easy to find one of those and easy to replace?
Get PriceLP Low Pressure Switch Check water flow to heat pump. . Clean your filter Low water flow. Make sure all valves are open Ensure pool filter pump is on Set unit to ACP if you have the heat / cool option. Refer to text on HPC-5 control board. Check pool temp. Wait until pool needs heat. High water temp Call HAYWARD service department for info.