Pressure reducing valve, pilot operated Type DR RE 26892/05.11 Replaces: 02.03 Table of contents Features – For subplate mounting RE 26892/05.11 DR Hydraulics Bosch Rexroth AG 3/12 Function, section Pressure valves type DR are pilot operated
Get PriceThe valve type ZDR is a direct operated pressure reducing valve in sandwich plate design with pressure limitation of the secondary circuit. It is used to reduce the system pressure. The pressure reducing valve basically comprises of a hous-ing (1), a control spool (2), a compression spring (3), adjust-ment type (4) and an optional check valve
Get Pricewww.boschrexroth.com/spc. Size 16. Component series 5X. Maximum operating pressure 250 bar. Maximum flow 220 l/min. Pressure reducing valve, pilot operated.
Get Price4/10 ZDR | Pressure reducing valve Bosch Rexroth AG, RE 26570, edition: 2018-03 Function, section The valve type ZDR is a direct operated pressure reducing valve in sandwich plate design with pressure limitation of the secondary circuit. It is used to reduce the system pressure. The pressure reducing valve basically comprises housing
Get PriceHydraulics Bosch Rexroth AG. RE 29145/06.07 DRG. 3/ 2. Function, section. Pressure control valves of type DRG are pilot operated pres- sure reducing valves.
Get PriceThey basically consist of main valve (1) with main spool insert (3) and pilot control valve (2) with pressure adjustment element. At rest, the valves are open, this means that fl uid can freely pass from port B, to port A via the main spool insert (3). Pressure present in port A acts on the under side of the main spool.
Get PriceCheck valve, optional (only for subplate mounting valves). Pressure reducing valve, pilot operated. Nominal sizes 10 to 32. Series 5X. Maximum operating
Get PricePRESSURE REDUCING VALVE 3DREP6C-2X/25EG24N9K4/M - official online store of Bosch Rexroth Corporation. us. Select your location. Location. Contact myRexroth Cart re29184_2011-06.pdf Download link; 3D CAD (STP) For this product we found matching spare parts in our Spare Parts Catalog
Get PriceThe valve type DR 6 DP is a direct operated pressure reducing valve in 3-way version, i.e. with pressure limitation of the secondary circuit. It is used to reduce a system pressure. The secondary pressure is set using the adjustment type (4). The valve is open in initial position.
Get Price18 17 T P XY 1 2 PT 1 P 2 3 Proportional pressure reducing valve | 3DR 5/18RE˜29286, edition: 2020-01, Bosch Rexroth AG Type 3DREE and 3DREME (with integrated electronics (OBE))
Get PriceDepending on the electric command value, these valves can be used to reduce the system pressure continuously. The valve is suitable for controlling couplings, pumps and direc- tional valves as well as for use in proportional pilot controls (particularly in the mobile area, however also for industrial ap- plications). ①= Main port 1 (A)
Get PriceREXROTH HIDRAULICA R900442490. Pressure reducing hydraulic valve is a device for reducing the pressure of a fluid. Downloadable PDF document.
Get PriceBosch Rexroth AG Hydraulics. ZDBY D / Z2DBY D RE 25722/11.07. Ordering data. Modular valve. Z. With 2 pressure valve. 2 cartridges (only enter for.
Get PricePressure reducing valve | Z3DR 3/10 RE 26874, edition: 2016-10, Bosch Rexroth AG Symbols (① = component side, ② = plate side) Type Z3DR 10 VP Valves of type Z3DR are pilot-operated 3-way pressure reducing valves with pressure limitation of the actuator in sandwich plate design. They serve for reduction and control of the system pressure.
Get PriceStandard types and standard units are contained in the. EPS (standard price list). Page 3. Hydraulics Bosch Rexroth AG. RE 25761/05.11 ZDB; Z2DB. 3/
Get PriceThe pressure reducing valve basically comprises housing. (1), control spool (2), compression spring (3), adjustment type (4) and an optional check valve. The
Get PriceRE 26874, edition: 2016-10, Bosch Rexroth AG. Pressure reducing valve, pilot-operated. Features. ▷ Sandwich plate valve. ▷ Porting pattern according to
Get PriceA pressure reducing valve ensures that a reduced pressure is maintained in defined areas of a hydraulic system. It is triggered if the pressure increases in the area of the valve. It blocks the flow to the controlled area until the pressure lies below the set value again. The valve basically consists of a valve housing, a pressure spring and a
Get PriceRE 58040/11. , Bosch Rexroth AG Features Direct operated proportional pressure reducing valve for reducing system pressure Cartridge valve Suitable for mobile and industrial applications Actuation via proportional solenoid In case of a power failure, the minimum pressure is set Recommended electronic controls:
Get PriceThe proportional pressure reducing valve type FTDRE 2 K is a direct-operated cartridge valve in 3-way version. It reduces the control pressure (port A) proportional to the solenoid current and works largely independently from the inlet pressure (port P). Minimum pressure is set in case of power failure or if the setpoint value is 0.
Get PricePilot Operated Pressure Reducing Valves. Hytec’s range of pilot operated pressure reducing valves caters for operating pressures of up to 350 bar. Various sizes, mountings and maximum flow ratings are available for leading performance standards, no matter your hydraulic application. View our pressure reducing valve specifications below.
Get Price